Tapered Insulation Solutions: Form

Our design services support the roofing contractor and structural designer, ensuring an accurate and customized overall solution.

The layout and placement of tapered insulation boards on a low-slope roof require advance planning. We offer a fast design service that enables the delivery of a pre-designed, dimensionally accurate, and customised solution to the construction site, complete with detailed layout drawings.

Why should roof slopes on low-slope roofs be created using PIR tapered insulation?

Roof slopes created with Recticel PIR tapered insulation are precise and consistent in quality. In addition, the insulation wedges are quick to install. Creating slopes with PIR tapered insulation does not significantly increase the self-weight of the structure, and installations can also be carried out during winter. The insulation wedges are also ideally suited for forming reverse slopes, correcting slopes on existing roofs, and improving drainage during roof renovation projects.

What information do we need for the design?

A clear quotation, smooth delivery, and detailed installation instructions improve efficiency and help keep the project on schedule. To prepare a detailed and dimensionally accurate design, we require the following basic information about the roofing project:

  • Roof plan drawing showing the area where slopes will be created using tapered insulation
  • Roof slope, e.g. 1:60
  • Any existing slopes in the roof deck structure and their directions
  • Exact locations of roof drains
  • Project information such as project phase, schedule, and required delivery date
  • Other additional information

Structure details, including target U-value:

  • Type of roof structure
  • Maximum and minimum thickness of the insulation layer

Preparing a preliminary quotation and using the design service is faster if the project’s base data is available in DWG format. Preparing detailed plans typically takes 3–7 working days.

You can also submit a request even if all details are not yet known — we will work together to find a suitable solution for the project.

ex. +32 475 00 00 00
ex. 8560
ex. 8560
Upload your tapered plan here
One file only.
8 MB limit.
Allowed types: pdf, dwg, jpg.
Upload your tapered plan here
One file only.
8 MB limit.
Allowed types: pdf, dwg, jpg.

Het plan/de tekening moet bevatten:
Alle afmetingen

  • Hoogtes van de dakranden, dakramen enz.

  • Een precieze locatie van alle regenwaterafvoeren
  • De locatie van alle dakramen, installaties, schoorstenen ...
  • Markeer de richting van de helling op het plan.

Stuur indien bekend ook de

  • Keuze van het conische product van Recticel Insulation: Eurothane Bi-4A of Eurothane Silver A
  • Gewenste afschot helling: 1/60 of 1/80 of 1/30 of 1/40
  • Minimale dikte of maximale dikte
  • Vereiste U-waarde in m²K/W